
Next Generation DNA Sequencing and Pcr Protocols & Manipulation
by Khan, Akbar S.; Cui, HelenBuy New
Rent Textbook
Used Textbook
We're Sorry
Sold Out
eTextbook
We're Sorry
Not Available
Summary
Following the human genome project, 454 was launched by 454 in 2005, and Solexa released Genome Analyzer the next year, followed by SOLiD (Sequencing by Oligo Ligation Detection) provided from Agencourt, which are three most typical massively parallel sequencing systems in the next generation sequencing (NGS) that shared good performance on throughput, accuracy, and cost compared with Sanger sequencing. These founder companies were then purchased by other companies: in 2006 Agencourt was purchased by Applied Biosystems, and in 2007, 454 was purchased by Roche, while Solexa was purchased by Illumina. After years of evolution, these three systems exhibit better performance and their own advantages in terms of read length, accuracy, applications, consumables, manpower requirement and informatics infrastructure, and so forth.
This book will compile and compare these major advances in DNA sequencing automation and PCR methodology.
Table of Contents
a.) A short history in PCR and DNA sequencing techniques
b.) Landmark molecular biology and life science advancement resulted from DNA sequencing and PCR techniques
Chapter II. Guiding principle and organization of the book
a.) Purpose, Objective, Scope
b.) Intended audience
c.) Flow and logic of the book
d.) Inclusions and exclusions, limitations
Block Two:
a.) Principle chemistry: sequencing by ligation
b.) Principle chemistry: sequencing by synthesis
c.) Leading NGS platforms
i. Ion Torrent PGM (Personal Genome Machine)
ii. Illumina HiSeq and MiSeq
iii. PacBio (Pacific Biosciences) RSII
iv. Other platforms: SOLiD, illumina GA (Genome Analyzer)
d.) Technical specifications to targeted utilities
Chapter IV. PCR instrument and applications in NGS
a.) Principles and instrument
b.) Basic chemistries
c.) Utility of NGS
Chapter V. Overview of utilities and comparative application
a.) Targeted analytic requirements
b.) Source material determination
c.) Microorganism genome sequencing
d.) Genome sequencing
e.) Transcriptome sequencing
f.) Chromatin immunoprecipitation sequencing
g.) Metagenome sequencing
h.) Epigenomic variation analysis
Block Three:
a.) Source material specific sample preparation
i. Infectious material inactivation
ii. Chemical and physical approaches
iii. Storage
b.) DNA/RNA Extraction
i. Instrument specification evaluation
--Quantity estimate (amount)
--Quality evaluation (fragment length)
ii. DNA extraction quality control
--Concentration measurement
--Quality evaluation
iii. RNA extraction quality control
--Concentration measurement
--Quality and sizing evaluation
c.) NGs cDNA Library Prep
i. Amplification-based library preparation
ii. Amplification-free library preparation
iii. DNA fragmentation
iv. Enzymatic treatment for DNA repair
v. Poly-A tailing of fragment
vi. Library validation
a.) Illumina
i. cDNA Library preparation from DNA extraction
--DNA fragmentation
--Adapter ligation
--PCR enrichment
--Comparison of commercial kits
ii. cDNA library preparation from RNA extraction
--mRNA selection
--polyA tail selection
--ribosome RNA removal
--DNA Fragmentation
--cDNA synthesis
--Ligation of adapters
--PCR enrichment
iii. Library validation
--Concentration measurement
--Sizing estimate
--Sequenceable concentration estimation
iv. Sequencing
--Instrument dependent condition
--Read lengths, number of reads and time requirement
b.) PacBio
i. DNA extraction
ii. Source material specific notation
iii. Library preparation of 10Kb template
--DNA Fragmentation
--Insert size determination
--Repair of DNA damage
--Repair of insert ends
--Blunt ligation
--Inactivation of ligate
--Digest of misligate product
c.) Library preparation of 20Kb template
--Fragmentation of DNA
--Insert size determination
--Repair of DNA damage
--Insert ends repair
--Blunt ligation
--Inactivation of ligate
--Digest of misligate product
--Size selection
d.) Sequencing primer annealing
e.) Binding Reaction
f.) Sequencing
--Binding of DNA polymerase to SMRT template
iii. Ion Torrent PGM, Ion Proton
--Library preparation
--Emulsion PCR
--Enrichment
--Quality control
--Sequencing
vii. SOLiD
a.) Platform specific considerations
i. Nucleic acid quality
ii. Quantity availability
iii. Read number requirement
iv. Read length requirement
v. Time
vi. Sequencing cost per Gb
b.) Sample Source material based selection
i. Microbial isolates, viral samples, animal, human, plant, environmental
ii. Formalin-fixed, paraffin-embedded samples
iii. Trace amount analysis
iv. Metagenomic
v. Single cell
c.) Research objective based selection
d.) Throughput based consideration
a.) SNP analysis from draft sequencing output
b.) Large scale small RNA study
c.) Landscape of human genome research
d.) Forensics application
a.) Barcoding, multiplexing
b.) Fragment sizing
c.) Kit selection and modification
Chapter XI. Future techniques
a.) Close to release: Oxford Nanopore
b.) In the horizon: Thumb-drive sequencer
c.) Prospect
Citations
Referencess
Notes
An electronic version of this book is available through VitalSource.
This book is viewable on PC, Mac, iPhone, iPad, iPod Touch, and most smartphones.
By purchasing, you will be able to view this book online, as well as download it, for the chosen number of days.
Digital License
You are licensing a digital product for a set duration. Durations are set forth in the product description, with "Lifetime" typically meaning five (5) years of online access and permanent download to a supported device. All licenses are non-transferable.
More details can be found here.
A downloadable version of this book is available through the eCampus Reader or compatible Adobe readers.
Applications are available on iOS, Android, PC, Mac, and Windows Mobile platforms.
Please view the compatibility matrix prior to purchase.